Kodak MIN-R S Film
Optimize mammography imaging in challenged processing environments
If you use shallow tanks for your mammogram film processing or share your processing in a mixed environment, count on KODAK MIN-R S Film for optimal image quality.
- Crisp, sharp images enhance viewing of minute details
- Choice of screens to meet particular needs imaging requirements
- Developed by the world leader in screen-film mammography
Fine detail perception
- Delivers sharp, crisp images to improve viewing ease and provide increased diagnostic information.
- High resolution provides enhanced perception of microcalcifications and other minute details, giving you greater interpretation confidence.
Innovative design
- Proprietary dual-emulsion film technology uses two thin emulsions working in tandem to yield a superb image with greater processing tolerance than a thicker single emulsion.
- Primary emulsion images breast parenchyma, providing detail and contrast, while the secondary emulsion images the breast periphery and upper density.
Flexibility that fits your environment
- MIN-R S Film fits into your existing workflow, requiring no adjustment to equipment or procedures in most cases.
- Compatible with all KODAK MIN-R screens, it also can be used with orthochromatic mammographic screens from other manufacturers.
Use with the complete KODAK system including processing chemistries, screens, cassettes and processors for optimal results.
|
Film
|
Screen
|
Processing Cycle
|
Relative Speed2
|
Contrast3
|
D-Max
|
|
RP
|
EX II
|
|
MIN-R S
|
MIN-R 2000
|
Standard
|
150
|
3.8
|
4.0
|
³
4.0
|
|
MIN-R S
|
MIN-R 2190
|
Standard
|
190
|
3.8
|
4.0
|
³
4.0
|
|
MIN-R S
|
MIN-R
|
Standard
|
100
|
3.8
|
4.0
|
³
4.0
|
1 Based on processing in KODAK X-OMAT Processors using seasoned KODAK X-OMAT EX II or KODAK RP X-OMAT Developer and KODAK RP X-OMAT LO Fixer at recommended temperatures.
2 Relative speed determined from matched-density radiographs.
3 Contrast measured as the average gradient between densities 0.25 and 2.00 above gross fog.
KODAK Mammography Screens
KODAK MIN-R Screens advanced technology that optimizes the performance of KODAK mammography films. The KODAK Film-Screen Systems include: KODAK MIN-R EV, KODAK MIN-R 2000 and KODAK MIN-R 2190 screens
KODAK Mammography Cassettes
Designed for use in mammography imaging, KODAK MIN-R 2 Cassettes is integrated as part of the KODAK MIN-R Film-Screen system.
KODAK Screen Cleaner for Mammography
The KODAK screen cleaner is specially formulated to optimize the superb image quality of the KODAK MIN-R Screen Film Systems.
MIN-R Screen Cleaner Wipes
MIN-R screen cleaner wipes are convenient, effective all-in-one cleaning tools to help keep KODAK MIN-R screens and cassettes free of dust and dirt that can cause minus-density artifacts on film.
KODAK X-OMAT EX II Developer and Replenisher
Highly recommended for processing KODAK MIN-R EV, KODAK MIN-R 2000 Plus, KODAK MIN-R 2000 and KODAK MIN-R S mammography films, it also has excellent results with all KODAK general radiography films.
KODAK RP X-OMAT Developer and Replenisher
KODAK RP X-OMAT developer and replenisher is our highest-quality, most versatile diagnostic film developer, suitable for standard, rapid, and extended processing.
KODAK RP X-OMAT LO Fixer and Replenisher
KODAK RP X-OMAT LO fixer and replenisher is formulated to enhance your working environment, image quality, and bottom line. Reduced odor, replenishment and environmental impact are among its benefits.
MIN-R S film
MIN-R 2000 Screen in MIN-R 2 cassette
MIN-R 2190 Screen in MIN-R 2 cassette